GW-1H
Power:1 HP
Speed: 3450r.p.m
Ultimate vacuum:60 Torr
Pumping speed:0.26 ~ 0.32 m³/min
Speed: 3450r.p.m
Ultimate vacuum:60 Torr
Pumping speed:0.26 ~ 0.32 m³/min
●Specifications of Single stage model
‧ Single stage model ideal
operation range: ATM ~ -600mmHg (760Torr ~ 160Torr)
●Performance testing conditions of Liquid Ring Vacuum Pumps as below:
Experimental conditions for gas discharging function listed on the catalogue include: inlet air temperature is 20℃, outlet pressure is 760 Torr, relative humidity is 75%, and sealing fluid temperature is 15℃. In case the actual sealing fluid temperature is higher or lower than 15℃, please modify it in accordance with Modification of Gas Discharging Function Table. Please avoid exceeding the red line zone to prevent from cavitation and noise.
●Accessories
Model |
Power (HP) |
Speed r.p.m |
Pumping speed m³/min |
Suction Port & Discharge Port inch |
Sealing Liquid Inlet inch |
Sealing Liquid Supply L/min |
Weight standard accessories (Non-motor) kg |
Weight standard accessories (With motor) kg |
|
GW-1H | 1 | 3450 | -640mmHg (120 Torr) | 0.26 | 1 | 1/4 | 5 | 23.5 | 38 |
---|---|---|---|---|---|---|---|---|---|
-590mmHg (170 Torr) | 0.29 | ||||||||
-490mmHg (270 Torr) | 0.32 | ||||||||
-400mmHg (360 Torr) |
0.32 |
‧ Ultimate vacuum: -700mmHg (60Torr)
●Performance testing conditions of Liquid Ring Vacuum Pumps as below:
Experimental conditions for gas discharging function listed on the catalogue include: inlet air temperature is 20℃, outlet pressure is 760 Torr, relative humidity is 75%, and sealing fluid temperature is 15℃. In case the actual sealing fluid temperature is higher or lower than 15℃, please modify it in accordance with Modification of Gas Discharging Function Table. Please avoid exceeding the red line zone to prevent from cavitation and noise.